{"id":10727,"date":"2025-03-12T09:35:16","date_gmt":"2025-03-12T09:35:16","guid":{"rendered":"https:\/\/nurs.essaybishops.com\/principles-of-magnetisation-and-relaxation-in-mri\/"},"modified":"2025-03-12T09:35:16","modified_gmt":"2025-03-12T09:35:16","slug":"principles-of-magnetisation-and-relaxation-in-mri","status":"publish","type":"post","link":"https:\/\/homeworkacetutors.com\/nursing\/principles-of-magnetisation-and-relaxation-in-mri\/","title":{"rendered":"Principles of Magnetisation and Relaxation in MRI"},"content":{"rendered":"<div class=\"content position-relative mb-4\">\n<p><strong>NAME:\u00a0NUR AFIFAH BINTI ABDUL RAHIM<\/strong><\/p>\n<h2><a id=\"_Toc387079504\" rel=\"nofollow\" target=\"_blank\"><\/a>LIST OF FIGURES<\/h2>\n<p><a href=\"#_Toc387079350\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Figure 1: The T1 relaxation curve.<\/a><\/p>\n<p><a href=\"#_Toc387079351\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Figure 2: The T2 decay curve.<\/a><\/p>\n<p><a href=\"#_Toc387079352\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Figure 3 : FID and spin echo.<\/a><\/p>\n<p><a href=\"#_Toc387079353\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Figure 4: The images of brain shows different image contrast.<\/a><\/p>\n<p><a href=\"#_Toc387079354\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Figure 5: T1 post-contrast demonstrating edema.<\/a><\/p>\n<p><a href=\"#_Toc387079355\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Figure 6: The sequences of RF pulse in a partial saturation recovery.<\/a><\/p>\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<h2><a id=\"_Toc387079507\" rel=\"nofollow\" target=\"_blank\"><\/a>INTRODUCTION<\/h2>\n<p>MRI images are obtained by measuring how rapidly hydrogen nuclei of different tissues return to their resting energy states after being excited by a strong magnetic field (<a href=\"#_ENREF_16\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">MacDonald-Jankowski, 2006<\/a>). The principles of MRI should be understood clearly to enable us produce good quality images for diagnosis.<\/p>\n<p>As the protons precess in the external magnetic field, they slowly align themselves in either parallel or anti parallel to the external magnetic field according to the energy level they possessed. At this rate, more protons align parallel to the external magnetic field (Bo) hence produce net vector magnetization (NMV) at longitudinal magnetization, Mz which value is maximum while the transverse magnetization, Mxy is zero (<a href=\"#_ENREF_2\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Borisjuk et al., 2013<\/a>). MR signal is only can be detected on Mxy, so we need to tilt Mz to Mxy.<\/p>\n<h2>1. <a id=\"_Toc387079508\" rel=\"nofollow\" target=\"_blank\"><\/a>Radiofrequency (RF) Pulse<\/h2>\n<h3><a id=\"_Toc387079509\" rel=\"nofollow\" target=\"_blank\"><\/a>1.190\u00b0 and 180\u00b0 RF pulse<\/h3>\n<p>RF pulse is commonly used in MRI for excitation, refocusing and inversion (<a href=\"#_ENREF_17\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Pang and Shen, 2007<\/a>). When the RF pulse is given, the protons will gain energy and resonance will occur if the energy given equals to the precessional frequency of the protons. The amplitude and duration of RF pulse determine the magnitude of the flip angle (<a href=\"#_ENREF_8\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Hancock, 2014<\/a>). 90\u00b0 RF pulse is used to tilt the vector away from longitudinal magnetization, Mz and transferred completely towards transverse plane results in transverse magnetization, Mxy (<a href=\"#_ENREF_11\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Hsu and Lowe, 2006<\/a>). 180\u00b0 pulse is required to rephrase or refocusing the protons and it rotates Mz directly opposite to external magnetic field, Bo with the number of protons are larger in anti-parallel states (<a href=\"#_ENREF_14\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Kobzar et al., 2012<\/a>).<\/p>\n<h2>2. <a id=\"_Toc387079510\" rel=\"nofollow\" target=\"_blank\"><\/a>Relaxation Time<\/h2>\n<p>As the RF pulse is turned off, the transverse magnetization slowly disappear while longitudinal magnetization reappeared, (<a href=\"#_ENREF_7\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Gultekin and Gore, 2005<\/a>).<\/p>\n<h3><a id=\"_Toc387079511\" rel=\"nofollow\" target=\"_blank\"><\/a>2.1T1 Recovery \u2013 Longitudinal Relaxation<\/h3>\n<p>T1 relaxation can be defined as the time when the magnetization has returned to 63% of its original value (<a href=\"#_ENREF_15\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Lakrimi et al., 2011<\/a>). T1 relaxation, also known as spin-lattice relaxation occur because as the vector from Mxy returns to Mz, they give up energy to the environment or lattice (<a href=\"#_ENREF_18\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Piechnik et al., 2013<\/a>) .<\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"https:\/\/s3-eu-west-1.amazonaws.com\/aaimagestore\/essays\/1003661.002.png\"\/ loading=\"lazy\"><\/p>\n<p><a id=\"_Toc387079350\" rel=\"nofollow\" target=\"_blank\"><\/a>Figure 1: The T1 relaxation curve (<a href=\"#_ENREF_8\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Hancock, 2014<\/a>).<\/p>\n<h3><a id=\"_Toc387079512\" rel=\"nofollow\" target=\"_blank\"><\/a>2.2T2 \/T2* Decay \u2013 Transverse Relaxation<\/h3>\n<p>T2 decay also known as spin-spin relaxation time determine the time of protons loss their phase as well as loss MR signal after RF pulse is turned off. It is also can be defined as the time taken to loss 63% of the transverse magnetization (<a href=\"#_ENREF_15\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Lakrimi et al., 2011<\/a>). T2 relaxation result from loss of energy to the adjacent nuclei (<a href=\"#_ENREF_13\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Key, 2007<\/a>). When the RF pulse is send in, all protons are in phase (phase coherence). However, the protons will lose it phase after RF pulse is turned off. Phase incoherent is caused by two factors which are the inhomegeneities if the external and internal magnetic field. The inhomogeneity of external magnetic field will cause additional transverse relaxation known as T2* decay (<a href=\"#_ENREF_5\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Chen et al., 2005<\/a>).<\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"https:\/\/s3-eu-west-1.amazonaws.com\/aaimagestore\/essays\/1003661.003.png\"\/ loading=\"lazy\"><\/p>\n<p><a id=\"_Toc387079351\" rel=\"nofollow\" target=\"_blank\"><\/a>Figure 2: The T2 decay curve (<a href=\"#_ENREF_8\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Hancock, 2014<\/a>).<\/p>\n<h2>3. <a id=\"_Toc387079513\" rel=\"nofollow\" target=\"_blank\"><\/a>Free Induction Decay (FID)<\/h2>\n<p>FID can be defined as loss of MR signal due to T2* effects. FID decays faster with the time constant T2* because of the inhomogeneities of external magnetic field (<a href=\"#_ENREF_23\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Yoshioka et al., 2009<\/a>). However, the signal can be recovered by using 180\u00b0 RF pulse and the signal produced is known as spin echo signal (<a href=\"#_ENREF_4\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Chavhan et al., 2009<\/a>).<\/p>\n<p><img decoding=\"async\" alt=\"C:UsersUiTMPicturesfid.png\" src=\"https:\/\/s3-eu-west-1.amazonaws.com\/aaimagestore\/essays\/1003661.004.png\"\/ loading=\"lazy\"><\/p>\n<p><a id=\"_Toc387079352\" rel=\"nofollow\" target=\"_blank\"><\/a>Figure 3 : FID and spin echo (<a href=\"#_ENREF_23\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Yoshioka et al., 2009<\/a>) .<\/p>\n<h2>4. <a id=\"_Toc387079514\" rel=\"nofollow\" target=\"_blank\"><\/a>Image Contrast<\/h2>\n<p>TR is time interval between applications of another 90 degree pulse in a sequence (<a href=\"#_ENREF_8\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Hancock, 2014<\/a>). TE is the time determines how much T2 decay is allowed to occur in the middle of a 90 degree pulse before signal is read (<a href=\"#_ENREF_6\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Fonseca, 2013<\/a>).<\/p>\n<h3>4.1 <a id=\"_Toc387079515\" rel=\"nofollow\" target=\"_blank\"><\/a>T1-Weighted Image (T1WI)<\/h3>\n<p>If short TR and TE are applied, T1-weighted image (T1WI) will be produced. Anatomy of a part is good to be demonstrated by using T1WI. Tissue with short T1 recovery for example fat will appear bright on the image as it emit high signal while tissue with long T1 recovery (water) is vice versa.<\/p>\n<h3><a id=\"_Toc387079516\" rel=\"nofollow\" target=\"_blank\"><\/a>4.2T2-Wieghted Image (T2WI)<\/h3>\n<p>If long TR and TE are used, T2-weighted image (T2WI) will be produced. TE long is needed so that differences in T2 can be manifested. Tissue with long T2 (water) will appear bright on the image while tissue with short T2 (fat) will appear dark.<\/p>\n<h3><a id=\"_Toc387079517\" rel=\"nofollow\" target=\"_blank\"><\/a>4.3 Proton Density Weighted Image (PDWI)<\/h3>\n<p>If long TR and short TE are applied, the image that will be produced is known as proton density weighted image (PDWI). The images produces are influenced by the number of protons they have. The larger the number of protons, the higher the signal will be produced.<\/p>\n<p><img decoding=\"async\" alt=\"File:T1t2PD.jpg\" src=\"https:\/\/s3-eu-west-1.amazonaws.com\/aaimagestore\/essays\/1003661.005.jpg\"\/ loading=\"lazy\"><\/p>\n<p><a id=\"_Toc387079353\" rel=\"nofollow\" target=\"_blank\"><\/a>Figure 4: The images of brain shows different image contrast. a) T1-weighted image \u2013 CSF (black), grey matter (grey), white matter (light grey) b) T2-weighted image \u2013 CSF (white), grey matter (grey), white matter (dark grey) c) PD weighted image \u2013 CSF (dark), grey matter (light grey) white matter (dark grey) (Weegenaar, n.d.).<\/p>\n<h2>5. <a id=\"_Toc387079518\" rel=\"nofollow\" target=\"_blank\"><\/a>Effect of Pathological and Contrast Media (CM) to Relaxation Time<\/h2>\n<p>Pathological processes in some tissue will alter the relaxation time hence produces changes in the signal intensity and contrast of the tissues in MR images (<a href=\"#_ENREF_1\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Berquist, 2012<\/a>). Pathologic tissues usually have longer T1 and T2 compared to normal tissue, hence, the tissue will manifest high contrast compared to its surrounding (<a href=\"#_ENREF_23\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Yoshioka et al., 2009<\/a>).<\/p>\n<p><img decoding=\"async\" alt=\"C:UsersAbd RahimPicturesfid.png\" src=\"https:\/\/s3-eu-west-1.amazonaws.com\/aaimagestore\/essays\/1003661.006.png\"\/ loading=\"lazy\"><\/p>\n<p><a id=\"_Toc387077304\" rel=\"nofollow\" target=\"_blank\"><\/a>Table 1: The table shows different pathologies that affect image contrast in MRI (Hesselink, n.d.).<\/p>\n<p>Both T1 and T2 relaxation time can be shortened by using contrast media to detect pathological tissue (<a href=\"#_ENREF_20\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Saeed and Wilson, 2012<\/a>). Pathological tissue in TI image will appear bright as CM increase the signal intensity while in T2 image, CM will produces broader lines with increased intensity (<a href=\"#_ENREF_23\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Yoshioka et al., 2009<\/a>).<\/p>\n<p><img decoding=\"async\" alt=\"T1 CM3.png\" src=\"https:\/\/s3-eu-west-1.amazonaws.com\/aaimagestore\/essays\/1003661.007.png\"\/ loading=\"lazy\"><\/p>\n<p><a id=\"_Toc387079354\" rel=\"nofollow\" target=\"_blank\"><\/a>Figure 5: T1 post-contrast demonstrating edema throughout the right fronto-parietal region with an enhancing, necrotic lesion within the anterior right frontal lobe (<a href=\"#_ENREF_3\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Chambless et al., 2010<\/a>).<\/p>\n<h2>6. <a id=\"_Toc387079519\" rel=\"nofollow\" target=\"_blank\"><\/a>Cell Characteristics Factor That Affect Relaxation Times<\/h2>\n<p>Different characteristics of cell will affect both T1 and T2 relaxation time (<a href=\"#_ENREF_21\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Shen, 2012<\/a>). The molecules of tissue which are closely packed together will induce faster energy transfer between the particles. This characteristic is related to T2 relaxation time (<a href=\"#_ENREF_22\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Westbrook et al., 2011<\/a>).<\/p>\n<p>Besides, molecules that have low inherent energy also have short T1 relaxation time. It is related to the ability of molecular lattice to easily absorb energy from hydrogen nuclei. It is related in T1 relaxation time (<a href=\"#_ENREF_22\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Westbrook et al., 2011<\/a>).<\/p>\n<h2>7. <a id=\"_Toc387079520\" rel=\"nofollow\" target=\"_blank\"><\/a>Partial Saturation Pulse Sequences<\/h2>\n<p>The pulse sequence parameters should be adjusted so that a high signal can be achieved (<a href=\"#_ENREF_19\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Pinus and Mohamed, 2010<\/a>). Partial saturation is different from saturation recovery pulse sequence based on the time interval given between pulses. (<a href=\"#_ENREF_10\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Holma and Sidarosa, 2006<\/a>). In partial saturation pulse sequence, TR short is applied so that the protons have not fully relaxed (<a href=\"#_ENREF_12\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Jordan et al., 2013<\/a>). T1WI will be produced in this pulse sequence. However, the sequences is said to be saturated if the second pulse is applied immediately after the first pulse, hence produce PDWI (<a href=\"#_ENREF_9\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Hashemi et al., 2010<\/a>).<\/p>\n<p><img decoding=\"async\" alt=\"C:UsersAbd RahimPicturesx1y0.png\" src=\"https:\/\/s3-eu-west-1.amazonaws.com\/aaimagestore\/essays\/1003661.008.png\"\/ loading=\"lazy\"><\/p>\n<p><a id=\"_Toc387079355\" rel=\"nofollow\" target=\"_blank\"><\/a>Figure 6: The sequences of RF pulse in a partial saturation recovery (<a href=\"#_ENREF_9\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Hashemi et al., 2010<\/a>).<\/p>\n<h2>CONCLUSION<\/h2>\n<p>The principles of MRI should be understood clearly to obtain images that can use for diagnosis. The importance of knowing the principles also need to be applied not just in theory but also during performing MRI examination. The functions of each parameters used in MRI also should be recognized as they play vital role in producing different type of images.<\/p>\n<p>(1091 words)<\/p>\n<h2><a id=\"_Toc387079522\" rel=\"nofollow\" target=\"_blank\"><\/a>REFERENCES<\/h2>\n<p><a id=\"_ENREF_1\" rel=\"nofollow\" target=\"_blank\"><\/a>Berquist, T. H. 2012. MRI of the Musculoskeletal System. Sixth ed. Philadelphia, USA: Lippincott Williams &amp; Wilkins.<\/p>\n<p><a id=\"_ENREF_2\" rel=\"nofollow\" target=\"_blank\"><\/a>Borisjuk, L., Rolletschek, H. &amp; Neuberger, T. 2013. Nuclear magnetic resonance imaging of lipid in living plants.<\/p>\n<p><a id=\"_ENREF_3\" rel=\"nofollow\" target=\"_blank\"><\/a>Chambless, L. B., Angel, F. B., Abel, Y. W., Xia, F. &amp; Weaver, K. D. 2010. Delayed cerebral radiation necrosis following treatment for a plasmacytoma of the skull.<\/p>\n<p><a id=\"_ENREF_4\" rel=\"nofollow\" target=\"_blank\"><\/a>Chavhan, G. B., Babyn, P. S., Thomas, B., Shroff, M. M. &amp; Haacke, E. M. 2009. Principles, Techniques, and Applications of T2*- based MR Imaging and Its Special Applications.<\/p>\n<p><a id=\"_ENREF_5\" rel=\"nofollow\" target=\"_blank\"><\/a>Chen, Q., Marble, A. E., Colpitts, B. G. &amp; Balcom, B. J. 2005. The internal magnetic field distribution, and single exponential magnetic resonance free induction decay, in rocks. <em>Journal of Magnetic Resonance<\/em><strong>,<\/strong> \u00c2\u008f<\/p>\n<p><a id=\"_ENREF_6\" rel=\"nofollow\" target=\"_blank\"><\/a>Fonseca, M. G. 2013. Spin Echo Magnetic Resonance Imaging.<\/p>\n<p><a id=\"_ENREF_7\" rel=\"nofollow\" target=\"_blank\"><\/a>Gultekin, D. H. &amp; Gore, J. C. 2005. Temperature dependence of nuclear magnetization and relaxation.<\/p>\n<p><a id=\"_ENREF_8\" rel=\"nofollow\" target=\"_blank\"><\/a>Hancock, J. 2014. <em>MRI Study Guide<\/em>, Australian Instistute of Radiography.<\/p>\n<p><a id=\"_ENREF_9\" rel=\"nofollow\" target=\"_blank\"><\/a>Hashemi, R. H., Bradley, W. G. &amp; Lisanti, C. J. 2010. MRI: The Basics. Third edition ed. Philadelphia, USA: Lippincott, Williams &amp; Wilkins.<\/p>\n<p><a id=\"_ENREF_10\" rel=\"nofollow\" target=\"_blank\"><\/a>Holma, D. A. &amp; Sidarosa, K. 2006. Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses. <em>Magnetic Resonance Imaging<\/em>.<\/p>\n<p><a id=\"_ENREF_11\" rel=\"nofollow\" target=\"_blank\"><\/a>Hsu, J.-J. &amp; Lowe, I. J. 2006. Encoding to the longitudinal magnetization for MR imaging and flow velocity mapping.<\/p>\n<p><a id=\"_ENREF_12\" rel=\"nofollow\" target=\"_blank\"><\/a>Jordan, C. D., Saranathan, M., Bangerter, N. K., Hargreaves, B. A. &amp; Gold, G. E. 2013. Musculoskeletal MRI at 3.0\u00a0T and 7.0\u00a0T: A comparison of relaxation times and image contrast. <em>European Journal of Radiology,<\/em> 82<strong>,<\/strong> 734-739.<\/p>\n<p><a id=\"_ENREF_13\" rel=\"nofollow\" target=\"_blank\"><\/a>Key, A. W. 2007. Magnetic Resonance Imaging.<\/p>\n<p><a id=\"_ENREF_14\" rel=\"nofollow\" target=\"_blank\"><\/a>Kobzar, K., Ehni, S., Skinner, T. E., Glaser, S. J. &amp; Luy, B. 2012. Exploring the limits of broadband 90 and 180 universal rotation pulses.<\/p>\n<p><a id=\"_ENREF_15\" rel=\"nofollow\" target=\"_blank\"><\/a>Lakrimi, M., Thomas, A. M., Hutton, G., Kruip, M., Slade, R., Davis, P., Johnstone, A. J., Longfield, M. J., Blakes, H., Calvert, S., Smith, M. &amp; Marshall, C. A. 2011. The principles and evolution of magnetic resonance imaging.<\/p>\n<p><a id=\"_ENREF_16\" rel=\"nofollow\" target=\"_blank\"><\/a>Macdonald-Jankowski, D. S. 2006. Magnetic Resonance Imaging. Part 1: The Basic Principles.<\/p>\n<p><a id=\"_ENREF_17\" rel=\"nofollow\" target=\"_blank\"><\/a>Pang, Y. &amp; Shen, G. X. 2007. Improving excitation and inversion accuracy by optimized RF pulse using genetic. 30 January 2007 ed.<\/p>\n<p><a id=\"_ENREF_18\" rel=\"nofollow\" target=\"_blank\"><\/a>Piechnik, S. K., Ferreira, V. M., Lewandowsk, A. J., Ntusi, N. A., Banerjee, R., Holloway, C., Hofman, M. B., Sado, D. M., Maestrini, V., White, S. K., Lazdam, M., Karamitsos, T., Moon, J. C., Neubauer, S., Leeson, P. &amp; Robson, M. D. 2013. Normal variation of magnetic resonance T1 relaxation times in the human population at 1.5 T using ShMOLLI. <em>Journal of Cardiovascular Magnetic Resonance<\/em>.<\/p>\n<p><a id=\"_ENREF_19\" rel=\"nofollow\" target=\"_blank\"><\/a>Pinus, A. B. &amp; Mohamed, F. B. 2010. fMRI Scanning Methodologies.<\/p>\n<p><a id=\"_ENREF_20\" rel=\"nofollow\" target=\"_blank\"><\/a>Saeed, M. &amp; Wilson, M. 2012. Value of MR contrast media in image-guided body interventions. <em>World Journal of Radiology<\/em>.<\/p>\n<p><a id=\"_ENREF_21\" rel=\"nofollow\" target=\"_blank\"><\/a>Shen, J. 2012. Preserving the excitation profile of small flip angle RF pulses in the presence of rapid transverse relaxation. <em>Journal of Magnetic Resonance<\/em>.<\/p>\n<p><a id=\"_ENREF_22\" rel=\"nofollow\" target=\"_blank\"><\/a>Westbrook, C., Roth, C. K. &amp; Talbot, J. 2011. <em>MRI in practice,<\/em> West Sussex, USA, Blackwell Publishing Ltd.<\/p>\n<p><a id=\"_ENREF_23\" rel=\"nofollow\" target=\"_blank\"><\/a>Yoshioka, H., Schlechtweg, P. M. &amp; Kose, K. 2009. Magnetic Resonance Imaging.<\/p>\n<p>1<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>NAME:\u00a0NUR AFIFAH BINTI ABDUL RAHIM LIST OF FIGURES Figure 1: The T1 relaxation curve. Figure 2: The T2 decay curve. Figure 3 : FID and\u2026<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2469,90,3568,3178,3567],"tags":[3573,3569,3570,1998,3572,2490,3574,3571],"class_list":["post-10727","post","type-post","status-publish","format-standard","hentry","category-health-care-essays","category-healthcare","category-nurscribe","category-nursing-discussion-post-example-essay","category-us","tag-healthcare-essay-service","tag-help-with-nursing-discussion-board","tag-i-need-help-writing-a-nursing-essay","tag-nursing-paper","tag-nursing-study-bay","tag-online-nursing-papers","tag-research-essay-pro-writers","tag-superior-nursing-papers"],"_links":{"self":[{"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/posts\/10727","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/comments?post=10727"}],"version-history":[{"count":0,"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/posts\/10727\/revisions"}],"wp:attachment":[{"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/media?parent=10727"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/categories?post=10727"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/homeworkacetutors.com\/nursing\/wp-json\/wp\/v2\/tags?post=10727"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}